VS1-24 Indoor High Voltage Vacuum Circuit Breaker with Common Insulated Cylinder (24kV)

The VS1-24 series indoor high-voltage vacuum circuit breaker is a reliable 24kV power distribution unit featuring a common insulated cylinder and composite insulation technology. Designed with a compact spring-charged operating mechanism and rod-push system, it offers stable performance and easily integrates with KYN28-24 (GZS1) switchgear to meet “Five Preventions” interlocking demands. With an M2-E2-C2 capability grade, this VCB is ideal for protecting and controlling electrical equipment in power plants, substations, and industrial facilities.

Product categories

VS1-24 Indoor High Voltage Vacuum Circuit Breaker with Common Insulated Cylinder (24kV)

Product Overview

The VS1-24 series indoor high-voltage vacuum circuit breaker is a robust three-phase AC 50Hz indoor power distribution unit with a rated voltage of 24kV. Designed for the protection and control of electrical equipment in power plants, substations, and industrial mining enterprises, this VCB utilizes a common insulated cylinder and composite insulation technology. Its compact design and reliable operation make it an ideal fit for KYN28-24 (GZS1) and similar medium-voltage switchgear.

Compact Design & Reliable Operation

This VS1-24 variant is engineered for high performance in constrained spaces:

  • Advanced Mechanism: Features a spring-charged operating mechanism paired with a rod-push system, ensuring stable and repeatable switching cycles.

  • High Capability Grade: Achieves a performance rating of M2-E2-C2, fully conforming to national standards and the latest IEC provisions.

  • Safety Integration: Easily matches with various switchgear models to meet the stringent “Five Preventions” interlocking demands of modern power systems.

  • Versatile Configurations: The series includes VCB trucks, isolation trucks, and fuse trucks to meet diverse application needs.

Technical Specifications

Item Unit Technical Data
Rated Voltage kV 24
Rated Current A 630 / 1250 / 1600 / 2000 / 2500 / 3150
Power Frequency Withstand Voltage (1min) kV 65
Lightning Impulse Withstand Voltage (Peak) kV 125
Rated Short-Circuit Breaking Current kA 20 / 25 / 31.5
Rated Short-Circuit Duration s 4
Rated Operating Sequence – O-0.3s-CO-180s-CO
Maximum D.C. Component % 50%

Applying Ambient Conditions

To ensure optimal performance, the VS1-24 should be operated within the following environmental limits:

  1. Ambient Temperature: Between -10°C and +40°C.

  2. Relative Humidity: Daily average ≤ 95%, Monthly average ≤ 90%.

  3. Altitude: Less than 1000m (excluding special custom requirements).

  4. Vapor Pressure: Daily average ≤ 2.2kPa, Monthly average ≤ 1.8kPa.

  5. Installation Site: Must be free from fire, explosion hazards, chemical corrosion, or violent vibration.