10kV 630A Medium Voltage RMU SF6 Load Break Switch – FLN36-12 Indoor LBS

The FLN36-12D/FLRN36-12D is a high-performance SF6 gas-insulated load break switch designed for medium voltage switchgear. Using SF6 gas for superior arc extinguishing and insulation, it provides three reliable working positions: Open, Closed, and Earth.

Key Highlights:

  • Versatile Operation: Available in K-type single spring (FLN36) or A-type double spring (FLRN36) mechanisms for different protection needs.

  • Compact & Durable: Optimized for space-saving installations in Ring Main Units (RMU), cable distribution boxes, and switching substations.

  • Safety First: The FLRN36-12D model supports fuse combinations to provide enhanced control and circuit protection.

  • Environmentally Adaptive: Designed for stable performance in diverse environmental conditions with easy installation.

产品类别

Product Description

The FLN36-12 series is a high-performance Medium Voltage RMU SF6 Load Break Switch designed for incoming lines in electrical distribution systems. Utilizing SF6 gas as the arc-extinguishing and insulating medium, this indoor switch ensures reliable performance within a compact design. It features a three-position rotary movable contact structure, supporting Closing, Opening, and Earthing states with integrated interlock safety.

Features

  • Dual Operating Mechanisms: Available as the FLN36-12D (K-type single spring) or FLRN 36-12D (A-type double spring). The A-type model can be equipped with fuse combinations for enhanced circuit protection.

  • Superior Insulation: The main circuit is sealed in a rugged epoxy resin housing, ensuring the conductive functions remain unaffected by external environmental influences.

  • High Safety Standards: Features an internal structural “weak point” in the housing to safely release overpressure in the event of internal arcing, protecting the cabinet and personnel.

  • Maintenance-Free Design: Compact, lightweight, and engineered for long-term operational safety without regular maintenance requirements.

  • Wide Application: Specifically optimized for Ring Main Units (RMU), cable distribution boxes, and switching substations.

Specifications

Item Unit FLN36-12D Data
Rated Voltage kV 12
Rated Current A 630
Rated Frequency Hz 50
Lightning Impulse Withstand Voltage kV 75
Rated Short-time Withstand Current (3s) kA 20
Rated Peak Withstand Current kA 50
Mechanical Endurance (LBS) Time 5000
SF6 Gas Pressure (20°C) bar 0.4
Main Circuit Resistance μΩ ≤ 65

Applications

  • Infrastructure: Power supply and switching substations.

  • Secondary Distribution: Ring Main Units (RMU) and cable distribution boxes.

  • Industrial Use: Protecting and controlling medium voltage electrical equipment.